Faults
11.4 Fault table
Fault Possible cause Remedy
Track marker not changing Working position sensor defec-
tive
Replace the work position sen-
sor
Hydraulic valve jamming Replace the hydraulic valve
Track marker switching too ear-
ly or too late
Work position sensor wrongly
set
Set the sensor
Working position sensor defec-
tive
Replace the work position sen-
sor
Tramline counter not working Stop key actuated Switch off the stop key
Work position sensor wrongly
set
Set the sensor
Tramline rhythm wrong Adjust tramline rhythm
Working position sensor defec-
tive
Replace the work position sen-
sor
Fan sensor alarmed Alarm limit wrongly set Alter the alarm limit
Oil volume too low or too high Set the oil volume
Fan sensor defective Replace the fan sensor
Working position sensor
not working
Working position sensor defec-
tive
Replace the working position
sensor
Slide in the distributor head
(tramlining control system) not
functioning
Clean the distributor head
Clean the control disc