6.4.23.5.4 Disconnecting the air and fertiliser supply on the rear hopper with central drive
1. Close the sliding shutter
on the fertiliser
metering unit.
CMS-I-00003915
2. Remove the fertiliser hose from the fertiliser
metering unit.
3. Seal the open connection with a cap
.
4. Install the clamp
.
5. Disconnect the air supply on the air distributor.
6. Seal the open connection with a cap
.
7. Install the clamp
.
CMS-I-00003917
6.4.23.5.5 Disconnecting the air and fertiliser supply on the distributor head
1. To interrupt the fertiliser
actuate the lever
.
The fertiliser is then conveyed back into the
corrugated tube and the conveyor air is diverted
close to the ground.
CMS-I-00003959