10-amp fuse Protected rows
Row 1 to 4
Row 5 to 8
Row 8 to 12
1. Clean the singling unit.
2. Check the singling disc for ease of movement.
3. Replace defective fuses.
Fuse for the mechanical drive is defective.
1. Remove the defective shear pin
.
2. Remove the defective shear pin from the drive
shaft
.
3. Clean the singling unit.
4. Check the singling disc for ease of movement.
5. Install the new shear pin
.
CMS-I-00002696
9.4.8 The fill level in the singling unit housing is too high.
The brushes of the filling block are worn.
The scraper removes excess seed from the singling
disc. If the brushes of the filling block are worn, the
seed does not flow back into the storage area
within the filling block.
To replace the defective block,
see "Changing the singling disc"
or
contact your specialist workshop.
CMS-I-00005635
CMS-T-00008170-A.1
9 | Repairing the machine
Eliminating faults
MG6660-EN-II | D.1 | 27.09.2021
232