Set analog timer recording via the menu.
Send <Timer Status> indicating that media is
available and timer programming has been set to the
DUT.
(Repeat this procedure with the logical address
changed to each of 1, 2, and 9.)
DUT sends <Set Analogue Timer> with all
parameters corresponding to the timer that
was set.
Set external timer recording via the menu.
Send <Timer Status> indicating that media is
available and timer programming has been set to the
DUT.
(Repeat this procedure with the logical address
changed to each of 1, 2, and 9.)
DUT sends <Set External Timer> with all
parameters corresponding to the timer that
was set.
Send <Set Digital Timer> from the DUT.
Return the <Timer Status> reply indicating that the
device could not be programmed to the DUT.
DUT does not add the record block to the
local list.
Send <Set Analogue Timer> from the DUT.
Return the <Timer Status> reply indicating that the
device could not be programmed to the DUT.
DUT does not add the record block to the
local list.
Send <Set External Timer> from the DUT.
Return the <Timer Status> reply indicating that the
device could not be programmed to the DUT.
DUT does not add the record block to the
local list.
Set digital timer recording via the EPG.
Send <Timer Status> indicating that media is
available and timer programming has been set to the
DUT.
Clear the timer recording via the EPG.
Send <Timer Cleared Status> indicating that
timer recording has been successfully cleared to the
DUT.
DUT sends <Clear Digital Timer> with all
parameters corresponding to the program
that was cleared.
DUT removes the timer program from that
display.
Set analog timer recording via the EPG.
Send <Timer Status> indicating that media is
available and timer programming has been set to the
DUT.
Clear the timer recording via the EPG.
Send <Timer Cleared Status> indicating that
timer recording has been successfully cleared to the
DUT.
DUT sends <Clear Analogue Timer> with all
parameters corresponding to the program
that was cleared.
DUT removes the timer program from that
display.
Set digital timer recording via the menu.
Send <Timer Status> indicating that media is
available and timer programming has been set to the
DUT.
Clear the timer recording via the menu.
Send <Timer Cleared Status> indicating that
timer recording has been successfully cleared to the
DUT.
DUT sends <Clear Digital Timer> with all
parameters corresponding to the timer that
was cleared.
DUT removes the timer program from that
menu.