EasyManua.ls Logo

ASTRO VA-1842 - CECT 12 Invalid Message Tests

ASTRO VA-1842
399 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Compliance Test
233
6.3.41 CECT 12 Invalid Message Tests
When “ALL TEST is selected, the tests for the test IDs are started. When a test ID number is clicked with the
mouse, only the selected test is started. The procedures for the tests performed with the VA-1842 are shown
below.
Item
Test procedure
Pass criteria
Invalid Message Tests
Connect the HDMI output of the DUT and the input of the TE. Then perform the tests.
12-1
Send a command, which should be sent by
broadcast, with a direct address instead.
Ignores the message.
12-2
Send a command, which should be sent with a direct
address, by broadcast instead.
Ignores the message.
12-3
Send an unsupported command.
Ignores the message.

Table of Contents