User's Manual 122 Document #: LTRT-42060
Mediant 2600 E-SBC
The static route's Gateway address in the Static Route table is in the same subnet as
the IP address of the IP network interface in the Interface table.
Figure 12-6: Example of using Static Route
12.5.2 Troubleshooting the Routing Table
When adding a new static route to the Static Route table, the added rule passes a
validation test. If errors are found, the static route is rejected and not added to the table.
Failed static route validations may result in limited connectivity (or no connectivity) to the
destinations specified in the incorrect static route. For any error found in the Static Route
table or failure to configure a static route, the device sends a notification message to the
Syslog server reporting the problem.
Common static routing configuration errors may include the following:
The IP address specified in the 'Gateway' field is unreachable from the IP network
interface associated with the static route.
The same destination is configured in two different static routes.
More than 30 static routes have been configured.
Note: If
a static route is required to access OAMP applications (for remote
management, for example) and the route is not configured correctly, the route is not
added and the device is not accessible remotely. To restore connectivity, the device
must be accessed l
ocally from the OAMP subnet and the required routes be
configured.