Version 6.8 425 Mediant 2600 E-SBC
User's Manual 28. High Availability Maintenance
28 High Availability Maintenance
This section describes various maintenance procedures for the High Availability mode.
28.1 Initiating an HA Switchover
You can initiate a switchover from the Active to Redundant device.
Note: When performing an HA switchover, the HA
mode becomes temporarily
unavailable.
To perform a switch-over:
1. Open the High Availability Maintenance page:
Navigation menu tree: Maintenance tab > Maintenance menu > High
Availability Maintenance
Toolbar: Click the Device Actions button, and then choose Switch Over
Figure 28-1: High Availability Maintenance Page
2. Under the 'Switch Over' group, click Switch Over; a confirmation box appears
requesting you to confirm.
3. Click OK.