User's Manual 28 Document #: LTRT-42060
Mediant 2600 E-SBC
b. In the 'Username' and 'Password' fields, enter the case-sensitive, default login
username ("Admin") and password ("Admin").
c. Click Login.
4. Open the Physical Ports Settings page (Configuration tab > VoIP menu > Network >
Physical Ports Table) and then configure the device's physical Ethernet port-pair
(group) that you want to later assign to the OAMP interface. For more information, see
Configuring Physical Ethernet Ports on page 105.
5. Open the Interface Table page (Configuration tab > VoIP menu > Network > IP
Interfaces Table).
6. Select the 'Index' radio button corresponding to the OAMP + Media + Control
application type, and then click Edit.
7. Change the IP address to correspond with your network IP addressing scheme, for
example:
IP Address: 10.8.6.86
Prefix Length: 24 (for 255.255.255.0)
Gateway: 10.8.6.85
Underlying Device: Select the Ethernet Device (VLAN and associated Ethernet
port group) for OAMP
8. Click Submit.
9. Save your settings by resetting the device with a flash burn (see ''Resetting the
Device'' on page 421).
10. Disconnect the device from the PC and cable the device to your network. You can
now access the management interface using the new OAMP IP address.
Note: When you complete the above procedure, change your PC's IP address to
correspond with your network requirements.