User's Manual 410 Document #: LTRT-42060
Mediant 2600 E-SBC
The Interface table below shows an example where the Maintenance interface is
assigned to Ethernet Device "vlan 2" (which is associated with Ethernet Port Group
"GROUP_2") in the 'Underlying Device' field, while the other interface is assigned to
"vlan 1" (associated with "GROUP_1"):
Figure 25-4: Configured MAINTENANCE Interface in Interface Table
2. If the connection is through a switch, the packets of both interfaces should generally
be untagged. In such a scenario, set the Native VLAN ID of each Ethernet Port Group
so that it is the same as the VLAN ID set for each interface assigned to that Ethernet
Port Group. The Native VLAN ID is configured in the Physical Ports Settings page
(see ''Configuring Physical Ethernet Ports'' on page 105). The figure below shows an
example whereby the Native VLAN IDs of the Ethernet Port Groups are set to the
same VLAN IDs of the interfaces using these Ethernet Port Groups:
Figure 25-5: Native VLAN for Ethernet Port Groups of Maintenance and Other Interfaces
3. Set the Ethernet port Tx / Rx mode of the Ethernet Port Group used by the
Maintenance interface. This is configured in the Ethernet Group Settings page (see
''Configuring Ethernet Port Groups'' on page 107). The port mode depends on the type
of Maintenance connection between the devices, as described in ''Network Topology
Types and Rx/Tx Ethernet Port Group Settings'' on page 407.
4. Configure the HA parameters in the HA Settings page (Configuration tab > System
menu > HA Settings):
Figure 25-6: HA Settings Page
a. In the 'HA Remote Address' field, enter the Maintenance IP address of the
second device.
b. (Optional) Enable the Revertive mode by setting the 'HA Revertive' parameter to
Enable and then setting the priority level of this device in the 'HA Priority' field.
5. Burn the configuration to flash without a reset.