User's Manual 50 Document #: LTRT-42060
Mediant 2600 E-SBC
The table below describes the areas of the Home page.
Table 6-7: Home Page Description
Item # Description
1 Displays the highest severity of an active alarm raised (if any) by the device:
Green: No alarms
Red: Critical alarm
Orange: Major alarm
Yellow: Minor alarm
To view active alarms, click the Alarms area to open the Active Alarms page (see
Viewing Active Alarms on page 479).
2 Fan tray unit status icon:
(green): Fan tray operating
(red): Fan tray failure
To view detailed information on the device's hardware components, click these icons
to open the Components Status page (see Viewing Hardware Components Status).
3 Power Supply module 2 status icon:
(green): Power Supply module is operating
(red): Power Supply module failure or no Power Supply module installed
To view detailed information on the device's hardware components, click these icons
to open the Components Status page (see Viewing Hardware Components Status).
4 Power Supply Unit 1 status indicator. See Item #3 for a description.
5 Chassis slot number.
6 Module status icon:
(green): Module has been inserted or is correctly configured
(gray): Module was removed. "Reserved" is displayed alongside the module's
name
(red): Module failure. "Failure" is displayed instead of the module's name
7 Media Processing Module (MPM).
Note: This is a customer-ordered module.
8 OK LED:
(red): Device undergoing startup
(green): Device startup has completed successfully