User's Manual 526 Document #: LTRT-42060
Mediant 2600 E-SBC
Batch Test Call Scenario: This example describes the configuration of a batch test
call setup for scheduled and continuous call testing of multiple endpoints. The test call
is done between two AudioCodes devices - Device A and Device B - with simulated
test endpoints. This eliminates the need for phone users, who would otherwise need
to answer and end calls many times for batch testing. The calls are initiated from
Device A, where Device B serves as the remote answering endpoint.
Figure 41-7: Batch Test Call Example
• Test Call table configuration at Device A:
♦ Endpoint URI: "101"
♦ Called URI: "201"
♦ Route By: Dest Address
♦ Destination Address: "10.13.4.12"
♦ Call Party: Caller
♦ Maximum Channels for Session: "3" (configures three endpoints - "101",
"102" and "103)
♦ Call Duration: "5" (seconds)
♦ Calls per Sec: "1"
♦ Test Mode: Continuous
♦ Test Duration: "3" (minutes)
♦ Schedule Interval: "180" (minutes)
• Test Call table configuration at Device B:
♦ Endpoint URI: "201"
♦ Maximum Channels for Session: "3" (configures three endpoints - "201",
"202" and "203)