Version 6.8 557 Mediant 2600 E-SBC
User's Manual 43. Configuration Parameters Reference
Parameter Description
EMS: Start
CLI: start
[DayLightSavingTimeStart]
can be configured using any of the following formats:
ï‚§ Day of year - mm:dd:hh:mm, where:
mm denotes month
dd denotes date of the month
hh denotes hour
mm denotes minutes
For example, "05:01:08:00" denotes daylight saving starting from
May 1 at 8 A.M.
ï‚§ Day of month - mm:day/wk:hh:mm, where:
mm denotes month (e.g., 04)
day denotes day of week (e.g., FRI)
wk denotes week of the month (e.g., 03)
hh denotes hour (e.g., 23)
mm denotes minutes (e.g., 10)
For example, "04:FRI/03:23:00" denotes Friday, the third week of
April, at 11 P.M. The week field can be 1-5, where 5 denotes the
last occurrence of the specified day in the specified month. For
example, "04:FRI/05:23:00" denotes the last Friday of April, at 11
P.M.
Web: End Time / Day of Month
End
EMS: End
CLI: end
[DayLightSavingTimeEnd]
Defines the date and time when daylight saving ends. For a
description of the format of this value, see the
DayLightSavingTimeStart parameter.
Web/EMS: Offset
CLI: offset
[DayLightSavingTimeOffset]
Defines the daylight saving time offset (in minutes).
The valid range is 0 to 120. The default is 60.
Note: The offset setting is applied only on the hour. For example, if
you configure this parameter at 15:42, the device applies the setting
only at 16:00.