User's Manual 586 Document #: LTRT-42060
Mediant 2600 E-SBC
Parameter Description
default is 150.
For configuration examples, see the description of the
GeneratedRegistersInterval parameter.
Generated Registers interval
gen-reg-int
[GeneratedRegistersInterval]
Defines the rate (in seconds) at which the device sends user
register requests (REGISTER messages). The parameter is
based on the maximum number of REGISTER messages that
can be sent at this rate, configured by the
MaxGeneratedRegistersRate parameter.
The valid value is 1 to 5. The default is 1.
Configuration examples:
If you configure the MaxGeneratedRegistersRate parameter
to 100 and the GeneratedRegistersInterval to 5, the device
sends a maximum of 20 REGISTER messages per second
(i.e., 100 messages divided by 5 sec; 100 per 5 seconds).
If you configure the MaxGeneratedRegistersRate parameter
to 100 and the GeneratedRegistersInterval to 1, the device
sends a maximum of a 100 REGISTER messages per
second.