SIP User's Manual 270 Document #: LTRT-12801
MP-500 MSBG
Column Name Description
 OK = Remote side responds to periodic connectivity queries.
 Lost = Remote side didn't respond for a short period.
 Fail = Remote side doesn't respond.
 Init = Connectivity queries not started (e.g., IP address not resolved).
 Disable = The connectivity option is disabled, i.e., parameter 'Alt Routing Tel
to IP Mode' (AltRoutingTel2IPMode ini) is set to 'None' or 'QoS'.
Quality Status
Determines the QoS (according to packet loss and delay) of the IP address.
 Unknown = Recent quality information isn't available.
 OK
 Poor
Notes:
 This parameter is applicable only if the parameter 'Alt Routing Tel to IP
Mode' is set to 'QoS' or 'Both' (AltRoutingTel2IPMode = 2 or 3).
 This parameter is reset if no QoS information is received for 2 minutes.
Quality Info.
Displays QoS information: delay and packet loss, calculated according to
previous calls.
Notes:
 This parameter is applicable only if the parameter 'Alt Routing Tel to IP
Mode' is set to 'QoS' or 'Both' (AltRoutingTel2IPMode = 2 or 3).
 This parameter is reset if no QoS information is received for 2 minutes.
DNS Status
DNS status can be one of the following:
 DNS Disable
 DNS Resolved
 DNS Unresolved