SIP User's Manual 362 Document #: LTRT-12801
MP-500 MSBG
Parameter Description
Web: Max Digits in Phone
Num
EMS: Max Digits in Phone
Number
[MaxDigits]
Defines the maximum number of collected destination number
digits that can be received (i.e., dialed) from the Tel side. When the
number of collected digits reaches the maximum, the device uses
these digits for the called destination number.
The valid range is 1 to 49. The default value is 5.
Notes:
 Digit Mapping Rules can be used instead.
 Dialing ends when any of the following scenarios occur:
9 Maximum number of digits is dialed
9 Interdigit Timeout (TimeBetweenDigits) expires
9 Pound (#) key is pressed
9 Digit map pattern is matched
Web: Inter Digit Timeout for
Overlap Dialing [sec]
EMS: Interdigit Timeout (Sec)
[TimeBetweenDigits]
Defines the time (in seconds) that the device waits between digits
that are dialed by the user. When this inter-digit timeout expires, the
<device> uses the collected digits to dial the called destination
number.
The valid range is 1 to 10. The default value is 4.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes mediapack MP-500 and is the answer not in the manual?

AudioCodes mediapack MP-500 Specifications

General IconGeneral
BrandAudioCodes
Modelmediapack MP-500
CategoryGateway
LanguageEnglish

Related product manuals