Parameter Description
EMS: Caller ID Timing Mode
[AnalogCallerIDTimingMode]
Determines when Caller ID is generated.
 [0] = Caller ID is generated between the first two rings
(default).
 [1] = The device attempts to find an optimized timing to
generate the Caller ID according to the selected Caller ID
type.
Notes:
 This parameter is applicable only to FXS interfaces.
 If this parameter is set to 1 and used with distinctive ringing,
the Caller ID signal doesn't change the distinctive ringing
timing.
 For this parameter to take effect, a device reset is required.
EMS: Bellcore Caller ID Type One
Sub Standard
[BellcoreCallerIDTypeOneSubSta
ndard]
Selects the Bellcore Caller ID sub-standard.
 [0] = Between rings (default).
 [1] = Not ring related.
Note: For this parameter to take effect, a device reset is
required.
EMS: ETSI Caller ID Type One Sub
Standard
[ETSICallerIDTypeOneSubStanda
rd]
Selects the ETSI FSK Caller ID Type 1 sub-standard (FXS
only).
 [0] = ETSI between rings (default).
 [1] = ETSI before ring DT_AS.
 [2] = ETSI before ring RP_AS.
 [3] = ETSI before ring LR_DT_AS.
 [4] = ETSI not ring related DT_AS.
 [5] = ETSI not ring related RP_AS.
 [6] = ETSI not ring related LR_DT_AS.
Note: For this parameter to take effect, a device reset is
required.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes mediapack MP-500 and is the answer not in the manual?

AudioCodes mediapack MP-500 Specifications

General IconGeneral
BrandAudioCodes
Modelmediapack MP-500
CategoryGateway
LanguageEnglish

Related product manuals