12-4.
TROUBLE
SHOOTING.
TROUBLE
PROBABLE
CAUSE
REMEDY
NO
FUEL
FLOW
TO
Fuel
selector
valve
not
turned
on.
Turn
valve
on.
CARBURETOR
Fuel
cells
empty.
Service
with
proper
grade
and
amount
of
fuel.
Fuel
line
disconnected
or
broken.
Connect
or repair
fuel
lines.
Fuel
cell
outlet
screen
plugged.
Remove
and
clean
screens
and
flush
out
fuel
cells.
Defective
fuel
selector
valve.
Repair
or
replace
selector
valve.
Inlet
elbow
or
inlet
screen
Clean
or
replace.
in
carburetor
plugged.
Plugged
fuel
strainer.
Remove
and
clean
strainr
and
screen.
Fuel
line
plugged.
Clean
or
replace
fuel line.
FUEL
STARVATION
AFTER
Partial
fuel
flow
from
the
pre-
Use
the
preceding
remedies.
STARTING
ceding
causes.
Pluged
fuel
vent.
Refer
to
paragraph
12-24.
Water
in
fuel.
Drain
fuel
cell
sumps,
lines
and
strainer.
NO
FUEL
QUANTITY
Fuel
cell
empty.
Service
with
proper
grade
and
INDICATION
amount
of
fuel.
Open
or
defective
circuit
breaker.
Reset.
Replace
if
defective.
Loose
connections
or
open
Tighten
connection;
repair
or
circuit.
replace
wiring.
Defective
fuel
quantity
indi-
Refer
to
Section
15.
cator
or
transmitter.
PRESSURIZED
FUEL
CELL
Plugged
bleed
hole
in
fuel
vent.
Refer
to
paragraph
12-24.
NO
FUEL
TO
CARBURETOR
Mechanical
fuel
Repair
or
replace
pump
defective.
mechanical
fuel
pump.
circuit
breaker
open.
circuitry
defective.
pump
or
pump
wiring.
12-2

Table of Contents