15-25.
TROUBLE
SHOOTING
--
VACUUM
SYSTEM.
TROUBLE
PROBABLE
CAUSE
REMEDY
HIGH
SUCTION
GAGE
READINGS.
Relief
valve
filter
clogged,
Replace
filter,
reset
valve.
(Gyros
function
normally.
)
relief
valve
malfunction.
Replace
Gage.
LOW
SUCTION
GAGE
READINGS.
Leaks
or
restriction
between
Repair
or
replace
lines,
adjust
or
instruments
and
relief
valve,
replace
relief
valve,
repair
or
re-
relief
valve
out
of
adjustment,
place
pump.
defective
pump.
Central
air
filter
dirty.
Replace
filter.
SUCTION
GAGE
FLUCTUATES.
Defective
gage
or
sticking
Replace
gage.
Clean
sticking
valve
relief
valve.
with
Stoddard
solvent.
Blow
dry
and
test.
If
valve
sticks
after
cleaning,
replace
it.
15-26.
TROUBLE
SHOOTING
--
GYROS.
TROUBLE
PROBABLE
CAUSE
REMEDY
HORIZON
BAR
FAILS
TO
RE-
Central
air
filter
dirty.
Replace
filter.
SPOND.
Suction
relief
valve
im-
Adjust
or
replace
relief
valve.
properly
adjusted.
Faulty
suction
gage.
Replace
suction
gage.
Vacuum
pump
failure.
Replace
pump.
Vacuum
line
kinked
or
Repair
or
replace
damaged
lines,
leaking.
tighten
connections.
HORIZON
BAR
DOES
NOT
Defective
mechanism.
Replace
instrument.
SETTLE.
Insufficient
vacuum.
Adjust
or
replace
relief
valve.
Excessive
vibration.
Replace
defective
shock
panel
mounts.
HORIZON
BAR
OSCILLATES
OR
Central
air
filter
dirty.
Replace
filter.
VIBRATES
EXCESSIVELY.
Suction
relief
valve
im-
Adjust
or
replace
relief
valve.
properly
adjusted.
Faulty
suction
gage.
Replace
suction
gage.
Defective
mechanism.
Replace
instrument.
Excessive
vibration.
Replace
defective
shock panel
mounts.