SERVICE
MANUAL
15-19.
TROUBLE
SHOOTING.
NOTE
Refer
to
paragraph
15-15
before
blowing
out
pitot
or
static
lines.
TROUBLE
PROBABLE
CAUSE
REMEDY
HAND
FAILS
TO
RESPOND.
Pitot
pressure
connection
Repair
or
replace
damaged
line,
not
properly
connected
to
pres-
tighten
connections.
sure
line
from
pitot
tube.
Pitot
or static
lines
clogged.
Blow
out
lines.
INCORRECT
INDICATION
OR
Leak
in
pitot
or
static
lines.
Repair
or
replace
damaged
HAND
OSCILLATES.
lines,
tighten
connections.
Defective
mechanism.
Replace
instrument.
Leaking
diaphragm.
Replace
instrument.
Alternate
static
source
valve
Close for
normal
operation.
open.
HAND
VIBRATES.
Excessive
vibration
caused
by
Tighten
mounting
screws.
loose
mounting
screws.
Excessive
tubing
vibration.
Tighten
clamps
and
connections,
replace
tubing
with
flexible
hose.
15-20.
TROUBLE
SHOOTING
--
ALTIMETER.
NOTE
Refer
to
paragraph
15-15
before
blowing
out
pitot
or
static
lines.
TROUBLE
PROBABLE
CAUSE
REMEDY
INSTRUMENT
FAILS
TO
Static
line
plugged.
Blow
out
lines.
OPERATE.
Defective
mechanism.
Replace
instrument.
INCORRECT
INDICATION.
Hands
not
carefully
set.
Reset
hands
with
knob.
Leaking
diaphragm.
Replace
instrument.
Pointers
out
of
calibration.
Replace
instrument.
HAND
OSCILLATES.
Static
pressure
irregular.
Blow
out
lines,
tighten
connections.
Leak
in
airspeed
or
vertical
Blow
out
lines,
tighten
connections.
speed
indicator
installations.
15-11