Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
Example: CONFigure: BRIGhtness HIGH
CONFigure: BRIGhtness NOR
CONFigure: BRIGhtness DIM
Query Syntax:: CONFigure: BRIGhtness?
Return Parameter: HIGH | NOR | DIM
Query Example: CONFigure: BRIGhtness ? Returns the brightness control
status of the panel.
Return Example: HIGH
13. CONFigure:MSTSLV:ID
Description: Sets the power supply to Master or Slave.
Syntax: CONFigure:MSTSLV:ID MASTER
CONFigure:MSTSLV:ID SLAVE1
Parameter: MASTER,SLAVE1,SLAVE2,SLAVE3…….SLAVE9.
Example: CONFigure:MSTSLV:ID MASTER
CONFigure:MSTSLV:ID SLAVE2
Query Syntax: CONFigure:MSTSLV:ID?
Return Parameter: MASTER | SLAVE1 | SLAVE2 | …… | SLAVE9
Query Example: CONF:MSTSLV:ID?
Return Example: MASTER or SLAVE1~SLAVE9
Note: CONFigure:MSTSLV? must be OFF when setting it. (Not in series/parallel mode.)
14. CONFigure:MSTSLV:PARSER
Description: Sets to series or parallel mode.
Syntax: CONFigure:MSTSLV:PARSER PARALLEL
CONFigure:MSTSLV:PARSER SERIES
Parameter: PARALLEL| SERIES
Example: CONFigure:MSTSLV:PARSER PARALLEL
CONFigure:MSTSLV:PARSER SERIES
Query Syntax: CONFigure:MSTSLV:PARSER?
Return Parameter: PARALLEL| SERIES
Query Example: CONF:MSTSLV:PARSER?
Return Example: PARALLEL
Note: CONFigure:MSTSLV? must be OFF when setting it. (Not in series/parallel mode.)
15. CONFigure:MSTSLV:NUMSLV
Description: Sets the number of SLAVEs to be controlled.
Syntax: CONFigure:MSTSLV:NUMSLV <NR1>
Parameter: <NR1>
Example: CONFigure:MSTSLV:NUMSLV 1
CONFigure:MSTSLV:NUMSLV 2
Query Syntax: CONFigure:MSTSLV:NUMSLV?
Return Parameter: <NR1>
Query Example: CONF:MSTSLV:NUMSLV?
Return Example: 1
1. CONFigure:MSTSLV? must be OFF when setting it. (Not in series/parallel
mode.)
2. Only 1 slave can be set when in series mode and a maximum of 9 slaves can
be set when in parallel mode.