Remote Operation
16. CONFigure:MSTSLV
Description: Executes the Master/Slave control.
Syntax: CONFigure:MSTSLV ON
CONFigure:MSTSLV OFF
Parameter: ON | OFF
Example: CONFigure:MSTSLV ON
CONFigure:MSTSLV OFF
Query Syntax: CONFigure:MSTSLV?
Return Parameter: ON| OFF
Query Example: CONF:MSTSLV?
Return Example: ON| OFF
1. Set the following 3 commands before using this function:
CONFigure:MSTSLV:ID
ONFigure:MSTSLV:PARSER
CONFigure:MSTSLV:NUMSLV
2. Series/parallel control is not available when Program RUN is active. To set
the series/parallel control, first exit the Program Mode.
17. CONFigure:INHibit
Description: Enables or Disables the Remote Inhibit control.
Syntax: CONFigure:INHibit <ARG>
Parameter: DISABLE| ENABLE
Example: CONFigure:INHibit DISABLE
CONFigure:INHibit ENABLE
Query Syntax: CONFigure:INHibit?
Return Parameter: DISABLE | ENABLE
Query Example: CONF:INH?
Return Example: DISABLE
18. CONFigure:INHibit:PULL
Description: Executes the Remote Inhibit input signal to enhance the resistance
control.
Syntax: CONFigure:INHibit:PULL <ARG>
Parameter: LOW|HIGH
Example: CONFigure:INHibit:PULL LOW
CONFigure:INHibit:PULL HIGH
Query Syntax: CONFigure:INHibit:PULL?
Return Parameter: LOW | HIGH
Query Example: CONF:INH:PULL?
Return Example: LOW
19. CONFigure:INTERLOCK
Description: Enables or Disables the Safety Interlock control.
Syntax: CONFigure:INTERLOCK <ARG>
Parameter: DISABLE| ENABLE
Example: CONFigure:INTERLOCK DISABLE
CONFigure:INTERLOCK ENABLE
Query Syntax: CONFigure:INTERLOCK?
Return Parameter: DISABLE | ENABLE
Query Example: CONF:INTERLOCK?
Return Example: DISABLE