EasyManua.ls Logo

Chroma A620028 - Page 202

Default Icon
238 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5-32
20. CONFigure:INTERLOCK:PULL
Description: Controls the internal resistance status of the Safety Interlock input
signal.
Syntax: CONFigure:INTERLOCK:PULL <ARG>
Parameter: LOW|HIGH
Example: CONFigure:INTERLOCK:PULL LOW
CONFigure:INTERLOCK:PULL HIGH
Query Syntax: CONFigure:INTERLOCK:PULL?
Return Parameter: LOW | HIGH
Query Example: CONF:INTERLOCK:PULL?
Return Example: LOW
21. CONFigure:EXTON
Description: Enables or Disables the External ON/OFF control.
Syntax: CONFigure: EXTON <ARG>
Parameter: DISABLE| ENABLE
Example: CONFigure: EXTON DISABLE
CONFigure: EXTON ENABLE
Query Syntax: CONFigure: EXTON?
Return Parameter: DISABLE | ENABLE
Query Example: CONF: EXTON?
Return Example: DISABLE
22. CONFigure: EXTON:PULL
Description: Controls the internal resistance status of the External ON/OFF input
signal.
Syntax: CONFigure: EXTON:PULL <ARG>
Parameter: LOW|HIGH
Example: CONFigure: EXTON:PULL LOW
CONFigure: EXTON:PULL HIGH
Query Syntax: CONFigure: EXTON:PULL?
Return Parameter: LOW | HIGH
Query Example: CONF: EXTON:PULL?
Return Example: LOW

Table of Contents