3.- UNIT INSTALLATION
3.1.- PRIOR RECOMMENDATIONS
In order to use the unit safely, it is critical that individuals who handle it follow the
safety measures set out in the standards of the country where it is being used,
use the necessary personal protective equipment, and pay attention to the vari-
ous warnings indicated in this instruction manual.
The CVM-B unit must be installed by authorised and qualied staff.
The power supply plug must be disconnected and measuring systems switched off before han-
dling, altering the connections or replacing the unit. It is dangerous to handle the unit while it is
powered.
Also, it is critical to keep the cables in perfect condition in order to avoid accidents, personal
injury and damage to installations.
The manufacturer of the unit is not responsible for any damage resulting from failure by the
user or installer to observe the warnings and/or recommendations set out in this manual, nor for
damage resulting from the use of non-original products or accessories or those made by other
manufacturers.
If an anomaly or malfunction is detected in the unit, do not use it to take any measurements.
Inspect the work area before taking any measurements. Do not take measurements in danger-
ous areas or where there is a risk of explosion.
Disconnect the unit from the power supply (unit and measuring system power
supply) before maintaining, repairing or handling the unit's connections.
Please contact the after-sales service if you suspect that there is an operational
fault in the unit.
10
CVM-B100 - CVM-B150
Instruction Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Circutor CVM-B100 and is the answer not in the manual?

Circutor CVM-B100 Specifications

General IconGeneral
TypePower Analyzer
Frequency Measurement Range45 - 65 Hz
Communication InterfaceRS-485 Modbus RTU
MountingDIN Rail
StandardsIEC 61010, IEC 61326
Current Measurement RangeUp to 6000 A via external CTs
Power MeasurementActive, Reactive, Apparent Power
MeasurementsVoltage, current, power, energy, frequency
DisplayLCD
AccuracyClass 0.5
Power Supply85-265 V AC / 95-300 V DC
Operating Temperature-10 to +50 °C
Storage Temperature-20 to 70 °C
Protection DegreeIP20