SAFETY PRECAUTIONS
DISCLAIMER
CIRCUTOR, SA reserves the right to make modi cations to the device or the unit speci ca-
tions set out in this instruction manual without prior notice.
CIRCUTOR, SA on its web site, supplies its customers with the latest versions of the device
speci cations and the most updated manuals.
www.circutor.com
DANGER
Warns of a risk, which could result in personal injury or material damage.
ATTENTION
Indicates that special attention should be paid to a speci c point.
Follow the warnings described in this manual with the symbols shown below.
If you must handle the unit for its installation, start-up or maintenance, the following
should be taken into consideration:
Incorrect handling or installation of the unit may result in injury to personnel as well as damage
to the unit. In particular, handling with voltages applied may result in electric shock, which may
cause death or serious injury to personnel. Defective installation or maintenance may also
lead to the risk of  re.
Read the manual carefully prior to connecting the unit. Follow all installation and maintenance
instructions throughout the unit’s working life. Pay special attention to the installation stan-
dards of the National Electrical Code.
Refer to the instruction manual before using the unit
In this manual, if the instructions marked with this symbol are not respected or carried out correctly, it can
result in injury or damage to the unit and /or installations.
CIRCUTOR, SA reserves the right to modify features or the product manual without prior noti cation.
3
Instruction Manual
CVM-B100 - CVM-B150

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Circutor CVM-B100 and is the answer not in the manual?

Circutor CVM-B100 Specifications

General IconGeneral
TypePower Analyzer
Frequency Measurement Range45 - 65 Hz
Communication InterfaceRS-485 Modbus RTU
MountingDIN Rail
StandardsIEC 61010, IEC 61326
Current Measurement RangeUp to 6000 A via external CTs
Power MeasurementActive, Reactive, Apparent Power
MeasurementsVoltage, current, power, energy, frequency
DisplayLCD
AccuracyClass 0.5
Power Supply85-265 V AC / 95-300 V DC
Operating Temperature-10 to +50 °C
Storage Temperature-20 to 70 °C
Protection DegreeIP20