EasyManuals Logo

Cisco Catalyst 3560-X User Manual

Cisco Catalyst 3560-X
1538 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1405 background imageLoading...
Page #1405 background image
1-25
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-25303-03
Chapter 1 Troubleshooting
Using the crashinfo Files
Basic crashinfo Files
The information in the basic file includes the Cisco IOS image name and version that failed, a list of the
processor registers, and a stack trace. You can provide this information to the Cisco technical support
representative by using the show tech-support privileged EXEC command.
Basic crashinfo files are kept in this directory on the flash file system:
flash:/crashinfo/.
The filenames are crashinfo_n where n is a sequence number.
Each new crashinfo file that is created uses a sequence number that is larger than any previously existing
sequence number, so the file with the largest sequence number describes the most recent failure. Version
numbers are used instead of a timestamp because the switches do not include a real-time clock. You
cannot change the name of the file that the system will use when it creates the file. However, after the
file is created, you can use the rename privileged EXEC command to rename it, but the contents of the
renamed file will not be displayed by the show stacks or the show tech-support privileged EXEC
command. You can delete crashinfo files by using the delete privileged EXEC command.
You can display the most recent basic crashinfo file (that is, the file with the highest sequence number
at the end of its filename) by entering the show stacks or the show tech-support privileged EXEC
command. You also can access the file by using any command that can copy or display files, such as the
more or the copy privileged EXEC command.
Extended crashinfo Files
The switch creates the extended crashinfo file when the system is failing. The information in the
extended file includes additional information that can help determine the cause of the switch failure. You
provide this information to the Cisco technical support representative by manually accessing the file and
using the more or the copy privileged EXEC command.
Extended crashinfo files are kept in this directory on the flash file system:
flash:/crashinfo_ext/.
The filenames are crashinfo_ext_n where n is a sequence number.
You can configure the switch to not create the extended creashinfo file by using the no exception
crashinfo global configuration command.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560-X and is the answer not in the manual?

Cisco Catalyst 3560-X Specifications

General IconGeneral
Enclosure TypeRack-mountable - 1U
SubtypeGigabit Ethernet
Ports48 x 10/100/1000 + 4 x SFP
Flash Memory64 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Operating SystemCisco IOS
Device TypeSwitch
PerformanceSwitching capacity: 128 Gbps
Jumbo Frame SupportYes
Routing ProtocolRIP-1, RIP-2, EIGRP
Remote Management ProtocolSNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, HTTP, HTTPS
FeaturesDHCP support, VLAN support, QoS, IPv6 support, Syslog
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1D, IEEE 802.1Q, IEEE 802.3ab, IEEE 802.1p, IEEE 802.3af, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1w, IEEE 802.1x, IEEE 802.1s, IEEE 802.3ah, IEEE 802.1ag, IEEE 802.3at
StackingStackable
Security FeaturesSSH, RADIUS, TACACS+
ManagementCLI
Dimensions (H x W x D)17.5 in
Operating Temperature32 to 113 °F (0 to 45 °C)
Humidity10 - 95% (non-condensing)