EasyManuals Logo

Cisco Catalyst 3560-X User Manual

Cisco Catalyst 3560-X
1538 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #494 background imageLoading...
Page #494 background image
1-6
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-25303-03
Chapter 1 Configuring VTP
Understanding VTP
Support for any database in a domain. In addition to propagating VTP information, version 3 can
propagate Multiple Spanning Tree (MST) protocol database information. A separate instance of the
VTP protocol runs for each application that uses VTP.
VTP primary server and VTP secondary servers. A VTP primary server updates the database
information and sends updates that are honored by all devices in the system. A VTP secondary
server can only back up the updated VTP configurations received from the primary server to its
NVRAM.
By default, all devices come up as secondary servers. You can enter the vtp primary privileged
EXEC command to specify a primary server. Primary server status is only needed for database
updates when the administrator issues a takeover message in the domain. You can have a working
VTP domain without any primary servers. Primary server status is lost if the device reloads or
domain parameters change, even when a password is configured on the switch.
The option to turn VTP on or off on a per-trunk (per-port) basis. You can enable or disable VTP per
port by entering the [no] vtp interface configuration command. When you disable VTP on trunking
ports, all VTP instances for that port are disabled. You cannot set VTP to off for the MST database
and on for the VLAN database on the same port.
When you globally set VTP mode to off, it applies to all the trunking ports in the system. However,
you can specify on or off on a per-VTP instance basis. For example, you can configure the switch
as a VTP server for the VLAN database but with VTP off for the MST database.
VTP Pruning
VTP pruning increases network available bandwidth by restricting flooded traffic to those trunk links
that the traffic must use to reach the destination devices. Without VTP pruning, a switch floods
broadcast, multicast, and unknown unicast traffic across all trunk links within a VTP domain even
though receiving switches might discard them. VTP pruning is disabled by default.
VTP pruning blocks unneeded flooded traffic to VLANs on trunk ports that are included in the
pruning-eligible list. Only VLANs included in the pruning-eligible list can be pruned. By default,
VLANs 2 through 1001 are pruning eligible switch trunk ports. If the VLANs are configured as
pruning-ineligible, the flooding continues. VTP pruning is supported in all VTP versions.
Figure 1-1 shows a switched network without VTP pruning enabled. Port 1 on Switch A and Port 2 on
Switch D are assigned to the Red VLAN. If a broadcast is sent from the host connected to Switch A,
Switch A floods the broadcast and every switch in the network receives it, even though Switches C, E,
and F have no ports in the Red VLAN.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560-X and is the answer not in the manual?

Cisco Catalyst 3560-X Specifications

General IconGeneral
Enclosure TypeRack-mountable - 1U
SubtypeGigabit Ethernet
Ports48 x 10/100/1000 + 4 x SFP
Flash Memory64 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Operating SystemCisco IOS
Device TypeSwitch
PerformanceSwitching capacity: 128 Gbps
Jumbo Frame SupportYes
Routing ProtocolRIP-1, RIP-2, EIGRP
Remote Management ProtocolSNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, HTTP, HTTPS
FeaturesDHCP support, VLAN support, QoS, IPv6 support, Syslog
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1D, IEEE 802.1Q, IEEE 802.3ab, IEEE 802.1p, IEEE 802.3af, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1w, IEEE 802.1x, IEEE 802.1s, IEEE 802.3ah, IEEE 802.1ag, IEEE 802.3at
StackingStackable
Security FeaturesSSH, RADIUS, TACACS+
ManagementCLI
Dimensions (H x W x D)17.5 in
Operating Temperature32 to 113 °F (0 to 45 °C)
Humidity10 - 95% (non-condensing)

Related product manuals