1-3
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-25303-03
Chapter 1 Configuring SPAN and RSPAN
Understanding SPAN and RSPAN
Figure 1-2 is an example of a local SPAN in a switch stack, where the source and destination ports reside
on different stack members.
Figure 1-2 Example of Local SPAN Configuration on a Switch Stack
Remote SPAN
RSPAN supports source ports, source VLANs, and destination ports on different switches (or different
switch stacks), enabling remote monitoring of multiple switches across your network. Figure 1-3 shows
source ports on Switch A and Switch B. The traffic for each RSPAN session is carried over a
user-specified RSPAN VLAN that is dedicated for that RSPAN session in all participating switches. The
RSPAN traffic from the source ports or VLANs is copied into the RSPAN VLAN and forwarded over
trunk ports carrying the RSPAN VLAN to a destination session monitoring the RSPAN VLAN. Each
RSPAN source switch must have either ports or VLANs as RSPAN sources. The destination is always a
physical port, as shown on Switch C in the figure.
Switch 1
1/0/4
2/0/15
Switch 2
Network
analyzer
Switch 3
Switch stack
159892
Stackwise Plus
port
connections
Port 4 on switch 1 in the stack
mirrored on port 15 on switch 2
Port 4 on switch 1 in the stack
mirrored on port 15 on switch 2
Port 4 on switch 1 in the stack
mirrored on port 15 on switch 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560-X and is the answer not in the manual?

Cisco Catalyst 3560-X Specifications

General IconGeneral
Enclosure TypeRack-mountable - 1U
SubtypeGigabit Ethernet
Ports48 x 10/100/1000 + 4 x SFP
Flash Memory64 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Operating SystemCisco IOS
Device TypeSwitch
PerformanceSwitching capacity: 128 Gbps
Jumbo Frame SupportYes
Routing ProtocolRIP-1, RIP-2, EIGRP
Remote Management ProtocolSNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, HTTP, HTTPS
FeaturesDHCP support, VLAN support, QoS, IPv6 support, Syslog
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1D, IEEE 802.1Q, IEEE 802.3ab, IEEE 802.1p, IEEE 802.3af, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1w, IEEE 802.1x, IEEE 802.1s, IEEE 802.3ah, IEEE 802.1ag, IEEE 802.3at
StackingStackable
Security FeaturesSSH, RADIUS, TACACS+
ManagementCLI
Dimensions (H x W x D)17.5 in
Operating Temperature32 to 113 °F (0 to 45 °C)
Humidity10 - 95% (non-condensing)