51-7
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 51 Troubleshooting
Recovering from a Lost or Forgotten Password
Step 1 Elect to continue with password recovery and lose the existing configuration:
Would you like to reset the system back to the default configuration (y/n)? Y
Step 2 Load any helper files:
Switch: load_helper
Step 3 Display the contents of flash memory:
switch: dir flash:
The switch file system appears:
Directory of flash:
13 drwx 192 Mar 01 1993 22:30:48 switch_image
16128000 bytes total (10003456 bytes free)
Step 4 Boot up the system:
Switch: boot
You are prompted to start the setup program. To continue with password recovery, enter N at the prompt:
Continue with the configuration dialog? [yes/no]: N
Step 5 At the switch prompt, enter privileged EXEC mode:
Switch> enable
Step 6 Enter global configuration mode:
Switch# configure terminal
Step 7 Change the password:
Switch (config)# enable secret password
The secret password can be from 1 to 25 alphanumeric characters, can start with a number, is case
sensitive, and allows spaces but ignores leading spaces.
Step 8 Return to privileged EXEC mode:
Switch (config)# exit
Switch#
Note Before continuing to Step 9, power on any connected stack members and wait until they have
completely initialized.
Step 9 Write the running configuration to the startup configuration file:
Switch# copy running-config startup-config
The new password is now in the startup configuration.
Note This procedure is likely to leave your switch virtual interface in a shutdown state. You can see
which interface is in this state by entering the show running-config privileged EXEC command.
To re-enable the interface, enter the interface vlan vlan-id global configuration command, and
specify the VLAN ID of the shutdown interface. With the switch in interface configuration
mode, enter the no shutdown command.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing