EasyManuals Logo

Cisco Catalyst 3750-X User Manual

Cisco Catalyst 3750-X
1438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #722 background imageLoading...
Page #722 background image
28-14
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 28 Configuring Port-Based Traffic Control
Configuring Port Security
Step 7
switchport port-security violation
{protect | restrict | shutdown |
shutdown vlan}
(Optional) Set the violation mode, the action to be taken when a security
violation is detected, as one of these:
protect—When the number of port secure MAC addresses reaches the
maximum limit allowed on the port, packets with unknown source
addresses are dropped until you remove a sufficient number of secure
MAC addresses to drop below the maximum value or increase the number
of maximum allowable addresses. You are not notified that a security
violation has occurred.
Note We do not recommend configuring the protect mode on a trunk port.
The protect mode disables learning when any VLAN reaches its
maximum limit, even if the port has not reached its maximum limit.
restrict—When the number of secure MAC addresses reaches the limit
allowed on the port, packets with unknown source addresses are dropped
until you remove a sufficient number of secure MAC addresses or
increase the number of maximum allowable addresses. An SNMP trap is
sent, a syslog message is logged, and the violation counter increments.
shutdown—The interface is error-disabled when a violation occurs, and
the port LED turns off. An SNMP trap is sent, a syslog message is logged,
and the violation counter increments.
shutdown vlan—Use to set the security violation mode per VLAN. In
this mode, the VLAN is error disabled instead of the entire port when a
violation occurs.
Note When a secure port is in the error-disabled state, you can bring it out
of this state by entering the errdisable recovery cause
psecure-violation global configuration command. You can manually
re-enable it by entering the shutdown and no shutdown in
terface
configuration commands or by using the clear errdisable interface
vlan privileged EXEC command.
Command Purpose

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing

Related product manuals