Display messages
9390 Reference manual 10-3
Message Meaning Action
Bad record type
XX
Data was corrupted during
XP programming.
Check the XP cables. Switch the
transceiver off and then on again.
If the problem remains, contact
your Codan agent for help.
Bad type/inst
XX/XX
The transceiver detected an
internal data fault.
Switch the transceiver off and
then on again. If the problem
remains, contact your Codan
agent for help.
BBRAM
Ck/Sum Err
Data in the battery backup
RAM has become
corrupted.
Contact your Codan agent for
help.
BBRAM update
failed
The transceiver cannot
read/write data to the
battery backup RAM.
Contact your Codan agent for
help.
Call stack
empty
There are no selcall, telcall
or page calls stored in the
call memory.
Refer to the 9390 User guide,
Chapter 6, Reviewing and
returning calls held in memory.
Channel not
found
This channel number is not
used.
Select a channel that exists.
Channel
protected
The selected channel is
protected against change or
deletion.
Contact your Codan agent if you
need to delete or change this
channel.
Channel space
full
The maximum number of
channels have been set up.
If you want to add channels, first
delete unwanted channels that are
not protected (NP). See
Chapter 3, Deleting a channel.
For protected channels (P),
contact your Codan agent for
help.