Display messages
9390 Reference manual 10-5
Message Meaning Action
Error: no self
ID
No selcall self ID has been
set up.
See Chapter 8, Selcall ID setup.
External RAM
bad
The transceiver cannot
read/write to parallel RAM
on power up.
Switch the transceiver off and
then on again. If the problem
remains, contact your Codan
agent for help.
Frequency not
found
No channel has been set up
for this frequency.
If you want to receive on this
frequency, see Chapter 3,
Creating a receive-only channel.
If you want to send on this
frequency, contact your Codan
agent.
FSK calibration
fail
The selcall decoder is not
calibrated.
Switch the transceiver off and
then on again. If the message
reappears, contact your Codan
agent for help.
I2C bus error
XXXX:XXXX
There is a major hardware
fault on one of the I
2
C bus
lines.
Contact your Codan agent for
help.
Intrnl Tmr
Alloc Err
The transceiver detected an
internal timer allocation
error.
Switch the transceiver off and
then on again. If the problem
remains, contact your Codan
agent for help.
Invalid IPC
channel
This channel is not
available for IPC-500 use.
Contact your Codan agent for
help.
Link established The transceiver has set up
an ALE link with the other
station.
Proceed with your call. For
details on ALE, see Chapter 5,
ALE option settings.
Link failed The transceiver failed to set
up an ALE link. The call
has failed.
Try sending another ALE call.
For details on ALE, see
Chapter 5, ALE option settings.
Contact your Codan agent if you
need help.