3-44 Compaq ProLiant ML570 Maintenance and Service Guide
Table 3-18
Array Diagnostic Utility (ADU) Error Messages
continued
Message Description Recommended Action
SCSI port X, Drive
ID YS.M.A.R.T.
predictive failure
errors
Have been detected
in the power Monitor
and Performance
data.
SOLUTION: Please
replace this drive
when conditions
permit.
A predictive failure warning for this
hard drive generates and indicates
a drive failure is imminent.
Replace this drive at the earliest opportunity.
See Hot-Plug Hard Drives in Chapter 2 prior to
performing this operation.
SCSI port X, Drive
ID Y was replaced on
a good volume:
(failure message)
ADU found this drive was replaced,
although there was no problem
with the volume.
No action needs to be taken.
Set configuration
command issued
The configuration of the array
controller has been updated. The
array accelerator board may remain
disabled until it is reinitialized.
Run the server setup utility to reinitialize the
array accelerator board.
Soft Firmware
Upgrade required
ADU has determined that your
controller is running firmware that
has been soft-upgraded by the
Compaq Upgrade Utility. However,
the firmware running is not present
on all drives. This could be caused
by the addition of new drives in the
system.
Run the Compaq Upgrade Utility to place the
latest firmware on all drives.
continued