Diagnostics and Troubleshooting 3-45
Table 3-18
Array Diagnostic Utility (ADU) Error Messages
continued
Message Description Recommended Action
Storage enclosure
on SCSI bus X has a
cabling error (bus
disabled).
SOLUTION: The SCSI
controller has an
internal and external
cable attached to the
same bus. Please
disconnect the
internal or external
cable from the
controller. If this
controller supports
multiple buses, the
cable disconnected
can be reattached to
an available bus.
The current cable configuration is
not supported.
Refer to your user documentation for cable
guidelines and reconfigure as indicated.
Storage enclosure
on SCSI bus X
indicated a door
alert.
SOLUTION: Be sure
that the storage
enclosure door is
closed or the side
panel is properly
installed.
The side panel of the external
storage unit is open.
Make sure the side panel of the storage unit is
securely closed.
Storage enclosure
on SCSI bus X
indicated a power
supply failure.
SOLUTION: Replace
the power supply.
A power supply in the external
storage unit has failed.
Replace the power supply.
continued