Diagnostics and Troubleshooting 3-15
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1771-Primary Disk
Port Address
Assignment Conflict
None Internal and external hard drive
controllers are both assigned to
the primary address.
Run the System Configuration
Utility and correct.
1772-Secondary
Disk Port Address
Assignment Conflict
None Address Assignment Conflict.
Internal and external hard drive
controllers are both assigned to
the secondary address.
Run the System Configuration
Utility and correct.
1773-Primary Fixed
Disk Port Assignment
Conflict
None Fixed disk drive error Run the System Configuration
Utility and correct.
1774-Slot x Drive
Array – Obsolete data
found in Array
Accelerator.
Select F1 to discard
contents of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
None SMART-2 Controller error Data found in array accelerator
is older than data found on
drives. Press F1 to discard the
older data in the array
accelerator and retain the
newer data on the drives.
1775-Slot x Drive
Array – ProLiant
Storage System Not
Responding SCSI
Port (y): Check
storage system
power switch and
cables. Turn the
system power off
while checking the
ProLiant power and
cable connections,
then turn the system
power back on to
retry.
None Storage system problem Power down the system. Check
external ProLiant power switch
– external drives must all be
powered up before or at the
same time as the main system.
Check cables. If retry does not
help, try replacing the cable,
ProLiant firmware, ProLiant
backplane, or the Smart Array
Controller.
1776-Drive Array
SCSI Port
Termination Error
None External and internal SCSI drives
are both configured to Port 1.
Reconfigure drives.
1777-Drive Array
External Drive
Subsystem Error
None Cooling fan failure, internal
temperature alert, or open side
panel
Inspect for cooling fan failure or
open side panel.
continued