DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
113
The fields that can be configured in LLDP-MED Settings are described below:
Parameter Description
Fast Start Repeat Count
Enter the LLDP-MED fast start repeat count value. This value must be between 1 and
10.
Click the Apply button to accept the changes made.
The fields that can be configured in LLDP Configurations are described below:
Parameter Description
Message TX Interval
Enter the interval between consecutive transmissions of LLDP advertisements on
each physical interface. The range is from 5 to 32768 seconds.
Message TX Hold Multiplier
Enter the multiplier on the LLDPDUs transmission interval that used to calculate
the TTL value of an LLDPDU. This value must be between 2 and 10.
ReInit Delay Enter the delay value for LLDP initialization on an interface. This value must be
between 1 and 10 seconds.
TX Delay
Enter the delay value for sending successive LLDPDUs on an interface. The valid
values are from 1 to 8192 seconds and should not be greater than one-fourth of
the transmission interval timer.
Click the Apply button to accept the changes made.
LLDP Port Settings
This window is used to display and configure the LLDP port settings.
To view the following window, click L2 Features > LLDP > LLDP Port Settings, as shown below:
Figure 5-58 LLDP Port Settings Window
The fields that can be configured are described below:
Parameter Description
From Port - To Port
Select the appropriate port range used for the configuration here.
Notification
Select to enable or disable the notification feature here.
Subtype Select the subtype of LLDP TLV(s). Options to choose from are MAC Address,
and Local.