Page #49 background image
Design Guide | iC7 Series Liquid-cooled System Modules
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
15
20 25 30
35 40 45 50 55 60
bar
l/min
e30bi160.10
Figure 36: Unit Pressure Drop with Water, INU IR12L without Filters (+AE10)
1.3
1.2
1.1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
1
0
2 4
6 8
10
12 14 16 18 20 22 24 26 28 30 32 34 35
bar
I/min
e30bg788.10
Figure 37: Pressure Drop with Water, LC Filter for AFE OF7Z1 (+AEZ1), 760 A
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
5 10 15 20 25 30 35
bar
l/min
e30bg791.10
Figure 38: Pressure Drop with Water, dU/dt Filter OF7U1 (+AEU1), 820 A
Danfoss Drives Oy © 2024.03 AJ475942178716en-000101 / 172K2848A | 49