Design Guide | iC7 Series Liquid-cooled System Modules
Table 78: Power Loss for INU Modules without Options, Modulator Type 2 (continued)
System module,
2 kHz switching
frequency
System module,
3 kHz switching
frequency
System module,
4 kHz switching
frequency
System module,
6 kHz switching
frequency
+AKFX
(1)
(1)
Model code Frame Rated
curren
t I
L(1/5)
[A]
Power
loss to
liquid
[kW]
Power
loss
to air
[kW]
Power
loss to
liquid
[kW]
Power
loss
to air
[kW]
Power
loss to
liquid
[kW]
Power
loss
to air
[kW]
Power
loss to
liquid
[kW]
Power
loss
to air
[kW]
Power
loss
to air
[kW]
iC7-60SLINB5-2080AE
00F_
3xIM1
2L
2080 12.02 0.12 14.19 0.14 14.96 0.15 17.84 0.18 0.20
iC7-60SLINB5-2300AE
00F_
3xIM1
2L
2300 13.76 0.14 16.25 0.16 17.06 0.17 20.42 0.20 0.23
iC7-60SLINB5-2500AE
00F_
3xIM1
2L
2500 15.44 0.15 18.27 0.18 19.16 0.19 22.88 0.23 0.31
iC7-60SLINB5-2830AE
00F_
4xIM1
2L
2830 16.46 0.16 19.43 0.19 20.46 0.20 24.46 0.24 0.26
iC7-60SLINB5-3050AE
00F_
4xIM1
2L
3050 18.17 0.18 21.52 0.22 22.57 0.23 26.97 0.27 0.31
iC7-60SLINB5-3260AE
00F_
4xIM1
2L
3260 20.06 0.20 23.60 0.24 24.86 0.25 29.66 0.30 0.48
1) DC fuses
10.7.14 Power Losses of DC/DC Converter Modules, Voltage Class 07
l The specifications for the values in the table
¢ DC/DC converter module
¢ DC voltage 1025 V DC
¢ Default switching frequency
¢ Power losses at rated low overload current I
L
, 50% duty cycle
Table 79: Power Loss for DC/DC Converter Modules
Frame System module System module with
+AED1
(1)
Product
code
System
module
System
module
with
+AED1
Nominal
current I
L
[A]
Power
loss to
liquid
[kW]
Power
loss to air
[kW]
Power
loss to
liquid
[kW]
Power
loss to air
[kW]
DC fuses
+AKFF
(2)
[kW]
Standby
loss [kW]
07-300A DM10L DR10L 300 2.61 0.03 2.94 0.06 0.08 0.07
07-360A DM10L DR10L 360 3.16 0.03 3.54 0.07 0.11 0.07
07-420A DM10L DR10L 420 3.76 0.04 4.20 0.09 0.13 0.07
07-480A DM10L DR10L 480 3.84 0.04 4.40 0.10 0.14 0.07
07-570A DM10L DR10L 570 4.08 0.04 4.87 0.13 0.19 0.07
Danfoss Drives Oy © 2024.03 AJ475942178716en-000101 / 172K2848A | 213