Fieldbus
Reference Manual 125
Digital Output Lines
Control Output 1
This parameter is configurable only if Digital Output 1 Use is set to Profibus/
Profinet. Select Disable or Enable from the drop-down list. If enabled, it allows the
Fieldbus Master to drive the Scanner Master or SC5000 Controller Output 1 via bit 0
in Byte 0 (first byte) of the Output Area.
Control Output 2
This parameter is configurable only if Digital Output 2 Use is set to Profibus/
Profinet. Select Disable or Enable from the drop-down list. If enabled, it allows the
Fieldbus Master to drive the Scanner Master or SC5000 Controller Output 2 via bit 1
in Byte 0 (first byte) of the Output Area.
3. When you have finished making changes, click Update All to save all pend-
ing changes, click Reset All
to revert to all previously saved values, and click
Reset Page to revert to previous saved values on the current page.