ENTER/EXIT PROGRAMMING MODE Codabar Enable/Disable
Product Reference Guide 197
CODABAR
The following options apply to the Codabar symbology.
Codabar Enable/Disable
When disabled, the reader will not read Codabar barcodes.
DEFAULT
Codabar = Disable
Codabar = Enable
Codabar Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Codabar check
character. When disabled, any check character in the label is treated as a data character
DEFAULT
Codabar Check Character Calculation = Don’t Calculate
Codabar Check Character Calculation = Enable AIM standard
check char.
Codabar Check Character Calculation = Enable Modulo 10
check char.