Display Features ENTER/EXIT PROGRAMMING MODE
278
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Keypad Select
This parameter specifies the character that has to be sent from the scanner when one of the three
keys are pressed. For example, when key1 is pressed a 0x3C '<' character is sent.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode
.
3. Scan the barcode: DISPLAY KEYPAD SELECT.
4. Then read 3 HEX characters in the range 01-FE from the keypad in Appendix D, Keypad,
corresponding to the left, center and right keys respectively.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
Disable Keypad
$
Enable Keypad Select
Make a mistake? Scan the CANCEL barcode to abort and not
save the en
try string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
3C3D3E