ENTER/EXIT PROGRAMMING MODE
50
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII
characters or any hex value from 0 to 0xFF can be selected. See page 293 for more information.
Select ACK Character Setting
DEFAULT
0x06 ‘ACK’ Character
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters
. 8-bit data is not
recognized when the option
Data Bits
has been set as 7 Data Bits.
NAK Character
This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII
characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters.
8-bit data is not
recognized when the option
Data Bits
has been set as 7 Data Bits.
See page 294 for more information.
Select NAK Character Setting
DEFAULT
0x15 ‘NAK’ Character