V1108, 8.8
you program X1 and an angle value (angular method) or in a projection measure.
Please ask the option description from your supplier when this option has been installed.
Only available when this option is installed.
Y opening default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Default Y-axis opening value.
The value programmed here is used as initial value for the parameter ‘Y-axis opening’ in
the Data Preparation menu of the programming mode.
Default pressing speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PS
Default pressing speed, used as initial value for the parameter ‘speed’ in a new
program.
Default wait for retract . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .WR
Default value for the parameter ‘wait for retract’ in a bend program. This parameter
determines the control behaviour in a bend program. Initially the parameter ‘wait for
retract’ is set to the value programmed here during postprocessing and during
programming.
The default value of this parameter = 0.
Default step change code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .XC
Default value for the parameter ‘step change code’ in a bend program. This parameter
determines the moment of step change in a bend program. Initially the code parameter
is set to the value programmed here during postprocessing and during programming.
The default value of this parameter is 2 (UDP).
See chapter ‘data preparation/data edit’ for more information about the ‘step change
code’ parameter.
Default delay time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .XT
During the postprocessing, the waiting time of the X-axis at step change is set to zero.
With this parameter you can preset a longer waiting time when needed for product
handling.
Default dwell time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .HT
Default value for the parameter ‘dwell time’ in a bend program.