Table 27. XR8620t Thermal Restriction - Raid Controller and Storage(ROR-N1)
Sled Config XR8620t Thermal Restriction
Ambient Temperature
ASHRAE
A2
(Max
35°C)
NEBS3
(Max
55°C)
GR3108C1-
L
(Max
55°C)
NEBS3-H
(Max
65°C)
GR3108C1+
(Max
65°C)
ROR-N1
M2
2280/221
10
Micron 7400
Hynix PE8010
2280 480G Supported Supported Supported Supported Supported
2280 800G Supported Supported Supported
Not
Supported
Not
Supported
2280 960G Supported Supported Supported
Not
Supported
Not
Supported
22110 1.92T Supported Supported Supported
Not
Supported
Not
Supported
Micron 7450
2280 480G Supported Supported Supported Supported Supported
2280 960G Supported Supported Supported
Not
Supported
Not
Supported
Hynix PE9010
2280 480G Supported Supported Supported Supported Supported
2280 960G Supported Supported Supported
Not
Supported
Not
Supported
2280 1.92T Supported Supported Supported
Not
Supported
Not
Supported
NOTE: The heater Manager subsystem is required for GR3108C1L and GR3108C1+ environment class.
Table 28. XR8620t Thermal Restriction - Raid Controller and Storage(Non-Raid Riser)
Sled Config XR8620t Thermal Restriction
Ambient Temperature
ASHRAE
A2
(Max
35°C)
NEBS3
(Max
55°C)
GR3108C1-
L
(Max
55°C)
NEBS3-H
(Max
65°C)
GR3108C1+
(Max
65°C)
Non-Raid
Riser
M2
2280/221
10
Micron 7400
Hynix PE8010
2280 480G Supported Supported Supported Supported Supported
2280 800G Supported Supported Supported
Not
Supported
Not
Supported
2280 960G Supported Supported Supported
Not
Supported
Not
Supported
22110 1.92T Supported Supported Supported
Not
Supported
Not
Supported
Micron 7450
2280 480G Supported Supported Supported Supported Supported
2280 960G Supported Supported Supported
Not
Supported
Not
Supported
Hynix PE9010
2280 480G Supported Supported Supported Supported Supported
2280 960G Supported Supported Supported
Not
Supported
Not
Supported
2280 1.92T Supported Supported Supported
Not
Supported
Not
Supported
NOTE: The heater Manager subsystem is required for GR3108C1L and GR3108C1+ environment class.