Table 29. XR8620t Thermal Restriction - Raid Controller and Storage(Mancini BOSS-N1)
Sled Config XR8620t Thermal Restriction
Ambient Temperature
ASHRAE
A2
(Max
35°C)
NEBS3
(Max
55°C)
GR3108C1-
L
(Max
55°C)
NEBS3-H
(Max
65°C)
GR3108C1+
(Max
65°C)
Mancini
BOSS-N1
M2 2280
Micron 7400
Hynix
PE8010
2280 480G Supported Supported
Not
Supported
Supported
Not
Supported
2280 800G Supported Supported
Not
Supported
Not
Supported
Not
Supported
2280 960G Supported Supported
Not
Supported
Not
Supported
Not
Supported
Micron 7450
2280 480G Supported Supported
Not
Supported
Not
Supported
Not
Supported
2280 960G Supported Supported
Not
Supported
Not
Supported
Not
Supported
Hynix
PE9010
2280 480G Supported Supported
Not
Supported
Not
Supported
Not
Supported
2280 960G Supported Supported
Not
Supported
Not
Supported
Not
Supported
2280 1.92T Supported Supported
Not
Supported
Not
Supported
Not
Supported
NOTE: The heater Manager subsystem is required for GR3108C1L and GR3108C1+ environment class.
Table 30. XR8620t Thermal Restriction - GPU
Sled Config XR8620t Thermal Restriction
Ambient Temperature
ASHRAE A2
(Max 35°C)
NEBS3
(Max 55°C)
GR3108C1-L
(Max 55°C)
NEBS3-H
(Max 65°C)
GR3108C1+
(Max 65°C)
Nvidia GPU L4 Supported Supported
Not
Supported
Not
Supported
Not
Supported
Table 31. XR8620t Thermal Restriction - Commodities
Sled Config XR8620t Thermal Restriction
Ambient Temperature
ASHRAE A2
(Max 35°C)
NEBS3
(Max 55°C)
GR3108C1-L
(Max 55°C)
NEBS3-H
(Max 65°C)
GR3108C1+
(Max 65°C)
PCIe Card
Above 55°C only PCIe cards with Extended Operating Temperature (EOT) Range is
supported for NEBS3-H & GR3108C1+.
Non-Dell PCIe cards are not supported.
Active Optical Cables/
Transceivers
Optic cables/transceivers with 70C spec is not supported for NEBS3-H & GR3108C1+.
Optic cables / transceivers with 85C spec can support up to 65°C.
PSU -
Dual PSUs are required.
Only eTemp range PSU is supported for NEBS3-H, GR3108C1L and
GR3108C1+.
NOTE: The heater Manager subsystem is required for GR3108C1L and GR3108C1+ environment class.
Technical specifications 29