Table 52. NVMe-oF SubSystem Settings screen details
Option Description
NVMe-oF SubSystem n (n = 1 to 4) Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
NVMe-oF SubSystem n Settings (n = 1
to 4)
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Table 53. NVMe-oF SubSystem Settings
Option Description
Interface NIC interface used for NVMe-oF connections.
Transport Type This field sets the value of transport type for NVMe-oF connection. This option is
set to TCP by default.
Protocol This field sets the value of protocol type for NVMe-oF connection. This option is
set to IPv4 by default.
VLAN Enables or disables VLAN for this NVMe-oF connections. This option is set to
Disabled by default.
VLAN Id Specifies the VLAN Id for this NVMe-oF connection. This option is set to 1 by
default.
VLAN Priority Specifies the VLAN priority for this NVMe-oF connection. This option is set to 0 by
default.
Retry Count Specifies the retry count for this NVMe-oF connection. This option is set to 3 by
default.
Timeout Specifies the time out for this NVMe-oF connection. This option is set to 10000 by
default.
DHCP Enables and disables the DHCP for this NVMe-oF connection. This option is set to
Disabled by default.
Host IP Address Specifies the Host IP Address for this NVMe-oF connection.
Host Subnet Mask Specifies the Host Subnet Mask for this NVMe-oF connection.
Host Gateway Specifies the Host Gateway for this NVMe-oF connection.
NVMe-oF Subsystem info via DHCP Enables and disables the NVMe-oF subsystem's DHCP for this connection. This
option is set to Disabled by default.
NVMe-oF Subsystem NQN Specifies the NVMe-oF subsystem's NQN for this connection.
NVMe-oF Subsystem Address Specifies the NVMe-oF subsystem's IP address for this connection.
NVMe-oF Subsystem Port Specifies the NVMe-oF subsystem's port for this connection. This option is set to
4420 by default.
NVMe-oF Subsystem NID Specifies the NamespaceID (NID) for this NVMe-oF connection.
NVMe-oF Subsystem Controller ID Specifies the NVMe-oF subsystem's Controller ID for this connection. This option
is set to 0 by default.
Security Enables or disables the security option for this NVMe-oF connection. This option is
set to Disabled by default.
Authentication Type Specifies the authentication type for this NVMe-oF connection. This option is set
to None by default.
SecuritykeyPath Specifies the SecuritykeyPath for this NVMe-oF connection.
46 Pre-operating system management applications