Chapter 12 Description of Parameter Settings
MH300
12.1-06-11
06-17
Fault Record 1
06-18
Fault Record 2
06-19
Fault Record 3
06-20
Fault Record 4
06-21
Fault Record 5
06-22
Fault Record 6
Default: 0
Display 0: No fault record
1: Over-current during acceleration (ocA)
2: Over-current during deceleration (ocd)
3: Over-current during steady operation (ocn)
4: Ground fault (GFF)
5: IGBT short circuit between upper bridge and lower bridge (occ)
6: Over-current at stop (ocS)
7: Over-voltage during acceleration (ovA)
8: Over-voltage during deceleration (ovd)
9: Over-voltage at constant speed (ovn)
10: Over-voltage at stop (ovS)
11: Low-voltage during acceleration (LvA)
12: Low-voltage during deceleration (Lvd)
13: Low-voltage at constant speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss protection (orP)
16: IGBT overheating (oH1)
17: Heatsink overheating (oH2)
18: IGBT temperature detection failure (tH1o)
19: Capacitor hardware error (tH2o)
21: Drive over-load (oL)
22: Electronic thermal relay protection 1 (EoL1)
23: Electronic thermal relay protection 2 (EoL2)
24: Motor overheating (PTC / PT100) (oH3)
26: Over-torque 1 (ot1)
27: Over-torque 2 (ot2)
28: Under current (uC)
29: Limit error (LiT)
31: EEPROM read error (cF2)
33: U-phase error (cd1)
34: V-phase error (cd2)
35: W-phase error (cd3)
36: cc (current clamp) hardware failure (Hd0)
37: oc (over-current) hardware failure (Hd1)