Chapter 8 Option CardsMH300
8-39
8-13 CMM-PD02 -- Communication Extension Card, Profibus DP
8-13-1 Product Profile
Figure 8-85
Figure 8-86
Wire: 0.25–0.5 mm
2
/ (24–20 AWG)
Stripping length: 7–8 mm
Torque: 2 kg-cm / (1.7 Ib-in.) / (0.2 Nm)
1. Screw fixing hole
2. Positioning hole
3. AC motor drive
connection port
4. Communication Port
5. Indicator light: NET1
6. Indicator light: POWER
7. Ground terminal block
8-13-2 Features
1. Supports PZD control data exchange.
2. Supports PKW polling AC motor drive parameters.
3.
Supports user diagnosis function.
4. Auto-detects baud rates; supports maximum of 12 Mbps
8-13-3 Specifications
PROFIBUS DP
Connector
Interface DB9 connector
Transmission
High-speed RS-485
Transmission cable Shielded twisted pair cable
Electrical isolation
500 V
DC
Table 8-36
Communication
Message type Cyclic data exchange
Module name CMM-PD02
GSD document DELA08DB.GSD
Product ID 08DB (hex)
Serial transmission
speed supported
(auto-detection)
9.6 kbps; 19.2 kbps; 93.75 kbps; 187.5 kbps; 125 kbps; 250 kbps; 500 kbps;
1.5 Mbps; 3 Mbps; 6 Mbps; 12 Mbps (bits per second)
Table 8-37
Electrical Specification
Power supply 15 V
DC
(supplied by AC motor drive)
Insulation voltage 500 V
DC
Power consumption 1 W
Weight 28 g
Table 8-38