Chapter 11 Summary of Parameter Settings
MH300
11-61
14 Protection Parameters (2)
Pr. Parameter Name
Setting Range
Default
14-00
Extension card input
terminal selection (AI10)
0: No function
1: Frequency command
(in MH300 series, this function can be the torque limit
in torque control mode)
2: Torque command (torque limit in speed mode)
3: Torque compensation command
4: PID target value
5: PID feedback signal
6: PTC thermistor input value
7: Positive torque limit
8: Negative torque limit
9: Regenerative torque limit
10: Positive / negative torque limit
11: PT100 thermistor input value
13: PID compensation amount
0
14-01
Extension card input
terminal selection (AI11)
0
14-02 AI10 Analog input bias -100.0100.0% 0.0
14-03 AI11 Analog input bias -100.0100.0% 0.0
14-04
AI10 positive / negative
bias mode
0: No bias
1: Lower than or equal to bias
2: Higher than or equal to bias
3: The absolute value of the bias voltage while serving as
the center
4: Bias serves as the center
0
14-05
AI11 positive / negative
bias mode
0
14-06 AI10 analog input gain -500.0500.0% 100.0
14-07 AI11 analog input gain -500.0500.0% 100.0
14-08
AI10 analog input filter
time
0.0020.00 sec. 0.01
14-09
AI11 analog input filter
time
0.0020.00 sec. 0.01
14-10
ACI10 analog input 420
mA signal loss selection
0: Disable
1: Continue operation at the last frequency
2: Decelerate to 0 Hz
3: Stop immediately and display ACE
0
14-11
ACI11 analog input 420
mA signal loss selection
0
14-12
AO10 extension card
output terminal selection
0: Output frequency (Hz)
0
1: Frequency command (Hz)
14-13
AO11 extension card
output terminal selection
2: Motor speed (Hz)
0
3: Output current (rms)
4: Output voltage
5: DC bus voltage