Chapter 12 Description of Parameter Settings
MH300
12.1-06-20
Status 3: The drive is in STOP; Pr.06-48 ≠ 0; Pr.07-02 ≠ 0
When the drive starts, it executes Pr.06-48 first, and then executes Pr.07-02 (DC brake). The
DC brake current level in this state includes two parts: one is 20 times the Pr.06-47 setting
value in Pr.06-48 setting time; the other is the Pr.07-01 setting value in Pr.07-02 setting time.
In this period.
Status 3-1: Pr.06-48 ≠ 0, Pr.07-02 ≠ 0 (No OPHL detected before operation)
Status 3-2: Pr.06-48 ≠ 0, Pr.07-20 ≠ 0 (OPHL detected before operation)
In this period, if an OPHL occurs within the time for Pr.06-48, the drive executes the Pr.06-
45 setting after the drive starts counting for half the time of Pr.06-48.