Chapter 12 Description of Parameter Settings
MH300
Emergency stop (EF) & force to stop selection
Default: 0
Settings 0: Coast to stop
1: Stop by the 1
st
deceleration time
2: Stop by the 2
nd
deceleration time
3: Stop by the 3
rd
deceleration time
4: Stop by the 4
th
deceleration time
5: System deceleration
6: Automatic deceleration
When the multi-function input terminal is set to EF input (setting 10) or forced to stop (setting 18)
and the terminal contact is ON, the drive stops according to the setting of this parameter.